User Guide-Titan

Specification

Titan Portable Decanter Chiller

Description

Dimension

285(L) x 190(W) x 83(H) mm

Weight

2.4KG / 5.29 lbs

Including a 500g/ 1.1 lbs rechargeable battery and a decanter

Battery

18V, 5,500mAh, 99Wh Life time 2.5~4 hours
Voltage 100~240V, 50~ 60Hz (input)
21.2V, 2.7A (output)
Full-voltage

 

Decanter
Material Glass
Capacity 1200 c.c. (Standard Usage 750 c.c.)
Dimension Outer diameter Ø 160mm, height 245mm, bottom diameter Ø 100mm.

Charging

 

① Dock Charging :

Connect the power adapter to the charging dock, then place the battery into the dock. The indicator light turns from red to green when charging is complete.

 

 

In-Unit Charging :

Insert the battery into the main unit and connect the power adapter to the device. The device must remain powered off during charging. The display shows the charging percentage.

How to Use

          Connect the charging cable or insert the battery to activate the TITAN Protable  electronic Decanter Chiler
Get wine from your wine cellar or refrigerator
          Retrieve wine from your wine cellar or refrigerator.
Pour wine into decanter
        Pour the wine into the decanter. 

Long press the power button for 2 seconds to activate the Titan Portable Decanter Chiller
Press and hold the control knob for 2 seconds to turn on the device.

Set the desired temperature and decanting time. The TITAN will maintain the selected temperature throughout the decanting process.

Indicators

Indicators 

LED Indicatior / Quick Guide

Long press the knob to power on/off the systemPower On
Press and hold the control knob for 2 seconds to turn on the device.

The VIVANT logo screen will be displayed with a startup sound.

Welcome

The welcome screen will be shown briefly, followed by the startup screen.
Display  Screen
On the display screen, the bottom-left indicates the set temperature. The top-left shows the temperature detected by the IR sensor. The bottom-right displays the set decanting time, while the top-right indicates the operating time / elapsed decanting time. The battery level is shown in the upper-left area of the display.
Set up
Set up mode

Short press the control knob to enter set up mode. The active setting will flash to indicate that it can be adjusted. Each short press advances to the next setting item. Rotate the knob clockwise or counterclockwise to make adjustments. After the fourth short press, the decanting process will begin.

Setting Temperature

In set up mode, rotate the knob clockwise to increase the temperature, or counter-clockwise to decrease the temperature.

The temperature can be set from 8°C–20°C (46°F–68°F).

Switch ℃/°F
Short press the button again to switch between Celsius and Fahrenheit temperature display. Rotate clockwise to select ℃, rotate counterclockwise to select °F.
 Setting Time

Rotate the control knob to adjust the desired decanting duration.

For safety protection, the TITAN will automatically power off 8 hours after the last operation. For extended decanting sessions, the device may be reactivated as needed to maintain temperature control while the device be attended during operation.



Target Reached

After confirming the decanting time, the decanting process will begin.

Once the target temperature and decanting time are reached, an audio alert will sound. The audio alert can be disabled through the VIVANT Wine App.

Long press the knob to power on/off the systemPower Off

Press and hold the knob for 2 seconds until the logo screen appears.

The device will power off after 5 seconds.

* After the display turns off, the shutdown process may still be in progress. Please wait briefly until the device has completely stopped operating before removing the battery or disconnecting the power cable.


Error Messages:
ERRORE 1: Batteria anomala o malfunzionante   ERROR 1 :Battery Abnormal or Malfunctioning.
ERRORE 2: Sensore a infrarossi anomali o malfunzionante   ERROR 2 :IR Sensor Abnormal or Malfunctioning
ERRORE 3: Ventola anomala o manfunzionante   ERROR 3 :Fan Abnormal or Malfunctioning

* Please scan the QR code to contact support

Notices

  • Before first use or after long-term storage, insert the battery into the unit (while powered off) or place it on the charging dock. Charge for 3–4 hours until fully charged.
  • To help extend battery life, we recommend charging the battery after each use.
  • To ensure proper heat dissipation, allow sufficient space around the device during operation.
  • For optimal heat conduction, ensure the bottom of the decanter is flat and in close contact with the cooling plate.
  • The battery is custom-designed for VIVANT products. Use only approved chargers and do not attempt to disassemble the battery.
  • For safety reasons, the device will automatically power off 8 hours after the last operation.
  • Do not place the device in high-temperature environments, such as dishwashers, microwaves, or ovens.
  • This device is intended for use by individuals with sufficient knowledge and experience, or under appropriate supervision. Children should be supervised to prevent unintended operation.